Produits Honeywell Sensing and Productivity Solutions - Capteurs de température - RTD (capteur de température à résistance) | Heisener Electronics
Contactez nous
SalesDept@heisener.com +86-755-83210559-810
Language Translation

* Please refer to the English Version as our Official Version.

Produits Honeywell Sensing and Productivity Solutions - Capteurs de température - RTD (capteur de température à résistance)

Dossiers 42
Page  1/2
Image
Référence
Fabricant
Description
paquet
Stock
Quantité
Tolerance
Current
Mounting Type
Package / Case
Thermistor Type
Voltage
Temperature
Accuracy
700-102AAC-B00
Honeywell Sensing and Productivity Solutions

TEMP SENSOR THIN FILM

  • Resistance: 1 kOhms
  • Tolerance: -
  • Current: -
  • Mounting Type: Free Hanging
  • Package / Case: Cylindrical Probe, Glass
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -
  • Accuracy: -
paquet: Cylindrical Probe, Glass
Stock8 442
-
-
Free Hanging
Cylindrical Probe, Glass
RTD
-
-
-
HRTS-5760-B-U-1-12
Honeywell Sensing and Productivity Solutions

HTRS DISCRETE AND PACKAGED RTD

  • Resistance: 1 kOhms
  • Tolerance: ±0.1%
  • Current: 1mA
  • Mounting Type: Free Hanging
  • Package / Case: Probe
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -200°C ~ 260°C
  • Accuracy: ±0.5°C
paquet: Probe
Stock7 614
±0.1%
1mA
Free Hanging
Probe
RTD
-
-200°C ~ 260°C
±0.5°C
HEL-716-U-0-12-00
Honeywell Sensing and Productivity Solutions

TEMPERATURE SENSOR PLATINUM RTD

  • Resistance: 1 kOhms
  • Tolerance: ±0.1%
  • Current: 1mA
  • Mounting Type: Free Hanging
  • Package / Case: Cylindrical Probe, Plastic
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -70°C ~ 260°C
  • Accuracy: ±0.3°C
paquet: Cylindrical Probe, Plastic
Stock5 724
±0.1%
1mA
Free Hanging
Cylindrical Probe, Plastic
RTD
-
-70°C ~ 260°C
±0.3°C
HEL-705-U-1-12-C1
Honeywell Sensing and Productivity Solutions

TEMPERATURE SENSOR PLATINUM RTD

  • Resistance: 1 kOhms
  • Tolerance: ±0.1%
  • Current: 1mA
  • Mounting Type: Free Hanging
  • Package / Case: Cylindrical Probe, Plastic
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -70°C ~ 260°C
  • Accuracy: ±0.5°C
paquet: Cylindrical Probe, Plastic
Stock8 622
±0.1%
1mA
Free Hanging
Cylindrical Probe, Plastic
RTD
-
-70°C ~ 260°C
±0.5°C
HEL-775-A-T-1
Honeywell Sensing and Productivity Solutions

TEMPERATURE SENSOR PLATINUM RTD

  • Resistance: 100 Ohms
  • Tolerance: ±0.1%
  • Current: 1mA
  • Mounting Type: Through Hole
  • Package / Case: Radial
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -55°C ~ 150°C
  • Accuracy: ±0.15%
paquet: Radial
Stock6 192
±0.1%
1mA
Through Hole
Radial
RTD
-
-55°C ~ 150°C
±0.15%
HEL-775-B-T-1
Honeywell Sensing and Productivity Solutions

TEMPERATURE SENSOR PLATINUM RTD

  • Resistance: 100 Ohms
  • Tolerance: ±0.1%
  • Current: 1mA
  • Mounting Type: Through Hole
  • Package / Case: Radial
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -55°C ~ 150°C
  • Accuracy: ±0.15%
paquet: Radial
Stock6 498
±0.1%
1mA
Through Hole
Radial
RTD
-
-55°C ~ 150°C
±0.15%
701-101BAA-B00
Honeywell Sensing and Productivity Solutions

PLATINUM RTD LEADED

  • Resistance: 100 Ohms
  • Tolerance: ±0.06%
  • Current: 1mA
  • Mounting Type: Through Hole
  • Package / Case: 2-SIP
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -70°C ~ 500°C
  • Accuracy: -
paquet: 2-SIP
Stock8 226
±0.06%
1mA
Through Hole
2-SIP
RTD
-
-70°C ~ 500°C
-
700-102BAA-B00
Honeywell Sensing and Productivity Solutions

PLATINUM RTD LEADED

  • Resistance: 1 kOhms
  • Tolerance: ±0.06%
  • Current: -
  • Mounting Type: Through Hole
  • Package / Case: Radial
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -30°C ~ 300°C
  • Accuracy: -
paquet: Radial
Stock8 478
±0.06%
-
Through Hole
Radial
RTD
-
-30°C ~ 300°C
-
HEL-777-A-T-0
Honeywell Sensing and Productivity Solutions

TEMPERATURE SENSOR PLATINUM RTD

  • Resistance: 100 Ohms
  • Tolerance: -
  • Current: -
  • Mounting Type: Through Hole
  • Package / Case: 2-SIP
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -55°C ~ 150°C
  • Accuracy: ±0.2%
paquet: 2-SIP
Stock6 300
-
-
Through Hole
2-SIP
RTD
-
-55°C ~ 150°C
±0.2%
R300-F35-M14-C
Honeywell Sensing and Productivity Solutions

TEMP SENSOR RTD 100 OHM PROBE

  • Resistance: 100 Ohms
  • Tolerance: ±3%
  • Current: -
  • Mounting Type: Chassis Mount
  • Package / Case: Chassis Mount
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -60°C ~ 300°C
  • Accuracy: -
paquet: Chassis Mount
Stock5 076
±3%
-
Chassis Mount
Chassis Mount
RTD
-
-60°C ~ 300°C
-
HEL-705-U-1-12-C2
Honeywell Sensing and Productivity Solutions

TEMPERATURE SENSOR PLATINUM RTD

  • Resistance: 1 kOhms
  • Tolerance: ±0.1%
  • Current: 1mA
  • Mounting Type: Free Hanging
  • Package / Case: Cylindrical Probe, Plastic
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -70°C ~ 260°C
  • Accuracy: ±0.5°C
paquet: Cylindrical Probe, Plastic
Stock7 668
±0.1%
1mA
Free Hanging
Cylindrical Probe, Plastic
RTD
-
-70°C ~ 260°C
±0.5°C
HEL-712-T-1-12-00
Honeywell Sensing and Productivity Solutions

TEMPERATURE SENSOR PLATINUM RTD

  • Resistance: 100 Ohms
  • Tolerance: ±0.2%
  • Current: 1mA
  • Mounting Type: Free Hanging
  • Package / Case: Cylindrical Probe, Plastic
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -75°C ~ 540°C
  • Accuracy: ±0.5°C
paquet: Cylindrical Probe, Plastic
Stock6 318
±0.2%
1mA
Free Hanging
Cylindrical Probe, Plastic
RTD
-
-75°C ~ 540°C
±0.5°C
HEL-707-U-0-12-00
Honeywell Sensing and Productivity Solutions

TEMPERATURE SENSOR PLATINUM RTD

  • Resistance: 1 kOhms
  • Tolerance: -
  • Current: 1mA
  • Mounting Type: Free Hanging
  • Package / Case: Probe
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -75°C ~ 540°C
  • Accuracy: -
paquet: Probe
Stock7 380
-
1mA
Free Hanging
Probe
RTD
-
-75°C ~ 540°C
-
HEL-711-U-1-12-00
Honeywell Sensing and Productivity Solutions

TEMPERATURE SENSOR PLATINUM RTD

  • Resistance: 1 kOhms
  • Tolerance: ±0.2%
  • Current: 1mA
  • Mounting Type: Free Hanging
  • Package / Case: Cylindrical Probe, Plastic
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -70°C ~ 260°C
  • Accuracy: ±0.5°C
paquet: Cylindrical Probe, Plastic
Stock6 372
±0.2%
1mA
Free Hanging
Cylindrical Probe, Plastic
RTD
-
-70°C ~ 260°C
±0.5°C
HEL-717-U-1-12-00
Honeywell Sensing and Productivity Solutions

TEMPERATURE SENSOR PLATINUM RTD

  • Resistance: 1 kOhms
  • Tolerance: ±0.2%
  • Current: 1mA
  • Mounting Type: Panel Mount
  • Package / Case: Cylindrical Probe Assembly
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -75°C ~ 540°C
  • Accuracy: ±0.5°C
paquet: Cylindrical Probe Assembly
Stock7 956
±0.2%
1mA
Panel Mount
Cylindrical Probe Assembly
RTD
-
-75°C ~ 540°C
±0.5°C
HEL-705-U-0-24-00
Honeywell Sensing and Productivity Solutions

TEMPERATURE SENSOR PLATINUM RTD

  • Resistance: 1 kOhms
  • Tolerance: ±0.2%
  • Current: 1mA
  • Mounting Type: Free Hanging
  • Package / Case: Cylindrical Probe, Plastic
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -70°C ~ 260°C
  • Accuracy: -
paquet: Cylindrical Probe, Plastic
Stock5 904
±0.2%
1mA
Free Hanging
Cylindrical Probe, Plastic
RTD
-
-70°C ~ 260°C
-
HEL-776-A-U-1
Honeywell Sensing and Productivity Solutions

HEL776 TEMP SENSOR PLATINUM RTD

  • Resistance: 1 kOhms
  • Tolerance: -
  • Current: -
  • Mounting Type: Through Hole
  • Package / Case: Radial
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -55°C ~ 150°C
  • Accuracy: ±0.1%
paquet: Radial
Stock8 568
-
-
Through Hole
Radial
RTD
-
-55°C ~ 150°C
±0.1%
700-101BAA-B00
Honeywell Sensing and Productivity Solutions

PLATINUM RTD LEADED

  • Resistance: 100 Ohms
  • Tolerance: ±0.12%
  • Current: -
  • Mounting Type: Through Hole
  • Package / Case: Radial
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -70°C ~ 500°C
  • Accuracy: -
paquet: Radial
Stock6 660
±0.12%
-
Through Hole
Radial
RTD
-
-70°C ~ 500°C
-
700-101BAB-B00
Honeywell Sensing and Productivity Solutions

PLATINUM RTD LEADED

  • Resistance: 100 Ohms
  • Tolerance: ±0.12%
  • Current: -
  • Mounting Type: Through Hole
  • Package / Case: Radial
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -70°C ~ 500°C
  • Accuracy: -
paquet: Radial
Stock7 176
±0.12%
-
Through Hole
Radial
RTD
-
-70°C ~ 500°C
-
TD4A
Honeywell Sensing and Productivity Solutions

SENSOR RTD LIQUID TEMP 2TERM

  • Resistance: 3.1 kOhms
  • Tolerance: -
  • Current: 1mA
  • Mounting Type: Panel Mount
  • Package / Case: Cylinder, Threaded
  • Thermistor Type: RTD
  • Voltage: 10VDC
  • Temperature: -40°C ~ 150°C
  • Accuracy: -
paquet: Cylinder, Threaded
Stock7 584
-
1mA
Panel Mount
Cylinder, Threaded
RTD
10VDC
-40°C ~ 150°C
-
HEL-777-A-U-0
Honeywell Sensing and Productivity Solutions

TEMPERATURE SENSOR PLATINUM RTD

  • Resistance: 1 kOhms
  • Tolerance: -
  • Current: -
  • Mounting Type: Through Hole
  • Package / Case: 2-SIP
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -55°C ~ 150°C
  • Accuracy: ±0.2%
paquet: 2-SIP
Stock6 372
-
-
Through Hole
2-SIP
RTD
-
-55°C ~ 150°C
±0.2%
HEL-705-T-1-12-00
Honeywell Sensing and Productivity Solutions

TEMPERATURE SENSOR PLATINUM RTD

  • Resistance: 100 Ohms
  • Tolerance: ±0.1%
  • Current: 1mA
  • Mounting Type: Free Hanging
  • Package / Case: Cylindrical Probe, Plastic
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -70°C ~ 260°C
  • Accuracy: ±0.5°C
paquet: Cylindrical Probe, Plastic
Stock6 840
±0.1%
1mA
Free Hanging
Cylindrical Probe, Plastic
RTD
-
-70°C ~ 260°C
±0.5°C
HRTS-5760-B-U-0-12
Honeywell Sensing and Productivity Solutions

HTRS DISCRETE AND PACKAGED RTD

  • Resistance: 1 kOhms
  • Tolerance: ±0.1%
  • Current: 1mA
  • Mounting Type: Free Hanging
  • Package / Case: Probe
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -200°C ~ 260°C
  • Accuracy: ±0.5°C
paquet: Probe
Stock8 802
±0.1%
1mA
Free Hanging
Probe
RTD
-
-200°C ~ 260°C
±0.5°C
HEL-776-A-U-0
Honeywell Sensing and Productivity Solutions

HEL 776 MOLDED SIP PKG 0.100

  • Resistance: 1 kOhms
  • Tolerance: -
  • Current: -
  • Mounting Type: Through Hole
  • Package / Case: Radial
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -55°C ~ 150°C
  • Accuracy: ±0.2%
paquet: Radial
Stock17 868
-
-
Through Hole
Radial
RTD
-
-55°C ~ 150°C
±0.2%
HEL-707-T-0-12-00
Honeywell Sensing and Productivity Solutions

TEMPERATURE SENSOR PLATINUM RTD

  • Resistance: 100 Ohms
  • Tolerance: -
  • Current: 1mA
  • Mounting Type: Free Hanging
  • Package / Case: Probe
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -75°C ~ 540°C
  • Accuracy: -
paquet: Probe
Stock6 264
-
1mA
Free Hanging
Probe
RTD
-
-75°C ~ 540°C
-
HEL-705-T-0-12-00
Honeywell Sensing and Productivity Solutions

TEMPERATURE SENSOR PLATINUM RTD

  • Resistance: 100 Ohms
  • Tolerance: ±0.2%
  • Current: 1mA
  • Mounting Type: Free Hanging
  • Package / Case: Cylindrical Probe, Plastic
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -70°C ~ 260°C
  • Accuracy: -
paquet: Cylindrical Probe, Plastic
Stock6 228
±0.2%
1mA
Free Hanging
Cylindrical Probe, Plastic
RTD
-
-70°C ~ 260°C
-
HEL-707-U-1-12-00
Honeywell Sensing and Productivity Solutions

TEMPERATURE SENSOR PLATINUM RTD

  • Resistance: 1 kOhms
  • Tolerance: -
  • Current: 1mA
  • Mounting Type: Free Hanging
  • Package / Case: Probe
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -75°C ~ 540°C
  • Accuracy: -
paquet: Probe
Stock6 696
-
1mA
Free Hanging
Probe
RTD
-
-75°C ~ 540°C
-
HEL-705-U-0-12-00
Honeywell Sensing and Productivity Solutions

1000 OHM PLATINUM RTD ELEMENT

  • Resistance: 1 kOhms
  • Tolerance: ±0.2%
  • Current: 1mA
  • Mounting Type: Free Hanging
  • Package / Case: Cylindrical Probe, Plastic
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -70°C ~ 260°C
  • Accuracy: -
paquet: Cylindrical Probe, Plastic
Stock6 696
±0.2%
1mA
Free Hanging
Cylindrical Probe, Plastic
RTD
-
-70°C ~ 260°C
-
HEL-705-U-1-12-00
Honeywell Sensing and Productivity Solutions

TEMPERATURE SENSOR PLATINUM RTD

  • Resistance: 1 kOhms
  • Tolerance: ±0.1%
  • Current: 1mA
  • Mounting Type: Free Hanging
  • Package / Case: Cylindrical Probe, Plastic
  • Thermistor Type: RTD
  • Voltage: -
  • Temperature: -70°C ~ 260°C
  • Accuracy: -
paquet: Cylindrical Probe, Plastic
Stock20 664
±0.1%
1mA
Free Hanging
Cylindrical Probe, Plastic
RTD
-
-70°C ~ 260°C
-
TD5A
Honeywell Sensing and Productivity Solutions

SENSOR RTD TEMP MINI 3LEAD

  • Resistance: 3.1 kOhms
  • Tolerance: -
  • Current: 1mA
  • Mounting Type: Through Hole
  • Package / Case: Radial, 3 Lead, Side View
  • Thermistor Type: RTD
  • Voltage: 10VDC
  • Temperature: -40°C ~ 150°C
  • Accuracy: -
paquet: Radial, 3 Lead, Side View
Stock79 686
-
1mA
Through Hole
Radial, 3 Lead, Side View
RTD
10VDC
-40°C ~ 150°C
-